Electromigration Effects in Overcurrent PVC-Insulated Copper Wire: Failure and Deformation Impacts

Muhammad Ali Akbar, Kerista Tarigan, Syahrul Humaidi, Dadan Ramdan, Yulianta Siregar

Abstract

Electromigration is a critical issue in materials science and electrical engineering, significantly impacting the reliability and efficiency of electrical systems. This study investigates the electromigration behavior of PVC-insulated copper wires under various overcurrent conditions, focusing on material degradation and electrical performance. Copper cables, identified as 046620.3 Eterna CU/PVC 1.5 mm2, were subjected to currents ranging from 0 to 110 A. The mean time to failure (MTTF) was calculated using Black’s equation, revealing a sharp decline in MTTF with increasing current density. Surface morphology analysis using SEM showed the formation of voids and hillocks at higher currents, indicating severe electromigration damage. XRF analysis demonstrated significant changes in the elemental composition, particularly a reduction in copper content and an increase in chlorine and other elements, suggesting degradation of the PVC insulation. FTIR spectroscopy revealed substantial chemical changes in the PVC material, especially under extreme overcurrent conditions, highlighting dehydrochlorination and carbonyl group formation. There is a clear relationship between overcurrent conditions and electromigration phenomena, as evidenced by the observed damage to surface morphology, changes in elemental composition, and alterations in the chemical structure of PVC. The mechanisms and causes of electromigration are explained comprehensively in this work, illustrating how increased overcurrent accelerates the electromigration process, leading to the formation of voids and hillocks in the copper conductor. This damage is accompanied by a significant reduction in copper content and an increase in chlorine levels, indicating the degradation of PVC insulation. FTIR spectra further confirmed these findings by showing chemical changes such as dehydrochlorination and carbonyl group formation under high current stress. The MTTF values reflect the severity of these impacts, with samples exposed to higher currents showing drastically reduced lifespans. For instance, samples subjected to 100 A and 110 A currents exhibited MTTF values of 0.2 minutes and 0.004 minutes, respectively.

References

Almaghamsi, H. (2024). The Impact of Bi3+ Ions on Magnetization, Dielectric Parameters, and Conductivity of Soft Mg-Cu Ferrite Nanoparticles. Journal of King Saud University - Science, 36(3), 103087.

Andritsos, K., Theodorakos, I., Zacharatos, F., & Zergioti, I. (2020). The Effect of Electromigration on the Lifetime and Performance of Flexible Interconnections Fabricated by Laser Printing and Sintering. Applied Surface Science, 506, 144968.

Bonardo, D., Darsono, N., Humaidi, S., Imaduddin, A., & Silalahi, N. S. (2023). Effect of Calcination Frequency on the Thermoelectric Properties of Ti Doped CuCrO2 by Solid State Method. Journal of Metals, Materials and Minerals, 33(4), 1785.

Ceric, H., de Orio, R. L., & Selberherr, S. (2023). Statistical Study of Electromigration in Gold Interconnects. Microelectronics Reliability, 147, 115061.

Cruz, P. P. R., da Silva, L. C., Fiuza-Jr, R. A., & Polli, H. (2021). Thermal Dehydrochlorination of Pure PVC Polymer: Part I-Thermal Degradation Kinetics by Thermogravimetric Analysis. Journal of Applied Polymer Science, 138(25), 50598.

Deng, J., Lin, Q., Li, Y., Wang, C., Wang, H., & Man, P. (2023). Effect of Overload Current Values on the Fire Characteristics of Polyethylene (PE) Copper Wires. Journal of Thermal Analysis and Calorimetry, 148(21), 11695–11705.

Estananto, E., Utari, L., Septiani, N. L. W., Bonardo, D., Nuruddin, A., Suyatman, S., & Yuliarto, B. (2023). Anatase TiO2 on Graphene-Coated Cotton Flexible Sensor at Room Temperature. In AIP Conference Proceedings (Vol. 2580, p. 050032).

Grosu, E. (2022). Applications of Polyvinylchloride (PVC)/Thermoplastic Nano-, Micro- and Macroblends. In Applications of Polyvinylchloride (PVC)/Thermoplastic Nano-, Micro- and Macroblends (pp. 75–89).

Hasan, A. A. Q., Alkahtani, A. A., Shahahmadi, S. A., Alam, M. N. E., Islam, M. A., & Amin, N. (2021). Delamination-and Electromigration-Related Failures in Solar Panels-A Review. Sustainability, 13(12), 6882.

Ho, P. S., Hu, C.-K., Gall, M., & Sukharev, V. (2022). Electromigration in Metals. Cambridge University Press.

Hua, X., Wang, L., & Yang, S. (2023). Multiscale Analysis of the Aging Process of Cable Insulation. IEEE Transactions on Dielectrics and Electrical Insulation, 30(1), 238–246.

Huang, Y. C., Tsai, M. Y., Lin, T. C., Lin, Y. S., Hung, C. P., & Lin, K. L. (2024). Microstructure and Growth of Cu Hillock on Redistribution Line Under Electromigration. Journal of Materials Science: Materials in Electronics, 35(9), 659.

Humaidi, S., Bonardo, D., Hasibuan, D., Sebayang, P., & Soehada, A. M. (2023). Experimental Study on Capillarity and Thermal of Metal Foam as the Wick Structure in Heat Pipe Application. In AIP Conference Proceedings (Vol. 2865, p. 040001).

Kotsovinos, P., Atalioti, A., McSwiney, N., Lugaresi, F., Rein, G., & Sadowski, A. J. (2020). Analysis of the Thermomechanical Response of Structural Cables Subject to Fire. Fire Technology, 56(2), 515–543.

Kurukuru, V. S. B., & Khan, I. (2022). Failure Mode Effect Analysis of Power Semiconductors in a Grid-Connected Converter. In Fault Analysis and its Impact on Grid-connected Photovoltaic Systems Performance (pp. 149–184). Wiley.

Li, Y., Zhang, R., Yang, K., Qi, Y., & Tu, R. (2024a). Numerical Investigations of AC Arcs’ Thermal Characteristics in the Short Gap of Copper-Cored Wires. Scientific Reports, 14(1), 4227.

Li, Z., Dong, Y., Wu, Y., Meng, Z., Song, P., Zhu, M., Li, X., & Du, B. (2024b). Breakdown Performance Evaluation and Lifetime Prediction of XLPE Insulation in HVAC Cables. Energies, 17(6), 1337.

Mokryak, A. Y., Mokryak, A. V., Skodtaev, S. V., & Safonova, T. V. (2022). Determination of the Causes of Copper Wires Beads after Fire in Vehicles. Materials Science Forum, 1049, 311–316.

Nassiet, V., Hassoune-Rhabbour, B., Tramis, O., & Petit, J.-A. (2021). Electrical and Electronics. In Adhesive Bonding (pp. 719–761). Elsevier.

Patil, J. J., Chae, W. H., Trebach, A., Carter, K., Lee, E., Sannicolo, T., & Grossman, J. C. (2021). Failing Forward: Stability of Transparent Electrodes Based on Metal Nanowire Networks. Advanced Materials, 33(5).

Prasad, S. P., Singh, Y., Vaitheeswaran, P. K., & Subbarayan, G. (2023). The Connection Between Electromigration Resistance and Thin-Film Adhesion and Their Degradation With Temperature. IEEE Transactions on Components, Packaging and Manufacturing Technology, 13(3), 426–443.

Tu, K. N., & Gusak, A. N. (2020). Mean-Time-To-Failure Equations for Electromigration, Thermomigration, and Stress Migration. IEEE Transactions on Components, Packaging and Manufacturing Technology, 10(9), 1427–1431.

Waliullah, M., Hossain, A.-M. A., Ojeda, B., Muzaffar, N., & Bernal, R. A. (2024). Electromigration Lifetime of Penta-Twinned Gold Nanowires: Implications for Flexible Electronics. ACS Applied Nano Materials, 7(7), 6906–6915.

Wang, W., Lu, C., Shi, L., Lyu, H., Ji, X., & Huo, Y. (2023). Numerical Simulation and Experimental Study on Metallographic Structure Characteristics of Melting Trace Caused by Overcurrent Fault of Copper Wire. Journal of Loss Prevention in the Process Industries, 83, 105065.

Zahedmaesh, H., Pedreira, O. V., Tokei, Z., & Croes, K. (2021). Electromigration Limits of Copper Nano-Interconnects. In 2021 IEEE International Reliability Physics Symposium (IRPS) (pp. 1–6).

Zhang, J., Huang, L., Chen, T., & Su, G. (2021). Simulation-Based Analysis of Electrical Fire Risks Caused by Poor Electric Contact Between Plug and Receptacle. Fire Safety Journal, 126, 103434.

Zhao, M., Feng, J. R., Li, Q., Lu, S., & Lin, J. (2024). Corrosion Behavior and Failure Mechanism of Ball Grid Array Packages in Fire Smoke Atmospheres. Engineering Failure Analysis, 156, 107811.

Zheng, X., Cai, G., Guo, J., Gao, W., Huang, Y., & Tong, X. (2023). Combustion Characteristics and Thermal Decomposition Mechanism of the Flame-Retardant Cable in Urban Utility Tunnel. Case Studies in Thermal Engineering, 44, 102887.

Zitao, J., Shaohua, D., Yunan, Z., Guanyi, L., & Tingtao, D. (2021). Corrosion of Copper Armor Caused by Induced Current in a 500 kV Alternating Current Submarine Cable. Electric Power Systems Research, 195, 107144.

Authors

Muhammad Ali Akbar
Kerista Tarigan
kerista@usu.ac.id (Primary Contact)
Syahrul Humaidi
Dadan Ramdan
Yulianta Siregar
Akbar, M. A., Tarigan, K., Humaidi, S., Ramdan, . D. ., & Siregar, Y. (2024). Electromigration Effects in Overcurrent PVC-Insulated Copper Wire: Failure and Deformation Impacts. Science and Technology Indonesia, 9(3), 735–744. https://doi.org/10.26554/sti.2024.9.3.735-744

Article Details